Latest News

 


 

 

Installation Notes

The following points must be noted when trying to communicate with the cash register.

1.For the ET 6600 / 6800 / 7626 set Main Flag 85 = 53, Main Flag 86 = 110000 for No Parity or 110111 for Even Parity.

...For the ET 5616 set Main Flag 44 = 53, Main Flag 45 = 110110 for No Parity or 110111 for Even Parity.

...For the TX 500 enter the following "56 X 0 CASH" for Even Parity and "56 X 1 CASH" for No Parity.

 

2.The wiring diagram for each cash register connected directly to a PC is as follows...

TX 500

ECR (RJ45)______________PC (9 Pin Female)

1---------------------------------8

2---------------------------------2

3---------------------------------7

4---------------------------------5

5 jumpered to 7 -------------------

8---------------------------------3

ET 5616

ECR (9 Pin Female)______________PC (9 Pin Female)

2---------------------------------3

3---------------------------------2

5---------------------------------5

7---------------------------------8

8---------------------------------7

ET 6600

ECR (8 Pin Din)______________PC (9 Pin Female)

1---------------------------------2

2---------------------------------3

3---------------------------------8

4---------------------------------7

5---------------------------------4

6---------------------------------5

8---------------------------------6

ET 6800

ECR (9 Pin Female)______________PC (9 Pin Female)

2---------------------------------3

3---------------------------------2

4---------------------------------6

5---------------------------------5

6---------------------------------4

7---------------------------------8

8---------------------------------7

3.The wiring diagram for each cash register connected to a modem or multiplexor is as follows...

TX 500

ECR (RJ45)______________Modem (25 Pin Male)

1---------------------------------4

2---------------------------------2

3---------------------------------5

4--------------------------------20

5 jumpered to 7 -------------------

8---------------------------------3

ET 5616

ECR (9 Pin Female)______________Modem (25 Pin Male)

2---------------------------------3

3---------------------------------2

5---------------------------------7

7---------------------------------4

8---------------------------------5

ET 6600

ECR (8 Pin Din)______________Modem (25 Pin Male)

1---------------------------------2

2---------------------------------3

3---------------------------------4

4---------------------------------5

5---------------------------------7

6---------------------------------6

8--------------------------------20

ET 6800

ECR (9 Pin Female)______________Modem (25 Pin Male)

2---------------------------------3

3---------------------------------2

4--------------------------------20

5---------------------------------7

6---------------------------------6

7---------------------------------4

8---------------------------------5

4. The following strings must be programmed into the cash register modem for it to operate. Use a terminal program, such as Hyper Terminal , to program the modem.

AT&F (loads default settings)

AT&N6 (sets fixed baud rate of 9600).Use this baud rate only.

ATS0=2 (picks up line after 2 rings)

For the TX 500 AT&D0 (ignores on-to-off transition of DTR)

AT&W (saves changes in RAM)

 

5. Please note that only Z2 information levels will be cleared for the TX 500.

 

6.The maximum levels set on the cash register for Departments and PLUs must correspond with the maximum levels set on the software.

 

7.For ET 7626 installatons, please note the eprom size being used and select the correct cash register model under ECR Network accordingly. The financial sales protocol differs on the 1 Meg eprom as opposed to the 4 Meg eprom. Selecting the wrong cash register model will result in incorrct or no Financial Sales information. Also note that where scanning is required, make sure that both the PC and scanner are connected on the same SIO 1 board. If the PC is connected on the SIO 2 board, communication errors will result while the cash register is in use.

 

8. For communication errors during transmission, set a Timeout value in milliseconds under Store Details.Try an initial value of 30 milliseconds.

 


 

 

Downloads

Date

File Name

Version

Description

14 November 2002

Convert Towa.exe

1.00

Converts Towalink database to ECR Software

27 November 2002

Backup.exe

1.00

Backup common ECR Software files

25 January 2003

ECR25Jan03.zip

2.08

Communication problems with 7626 have been rectified.

VAT sales and VAT paid now appears on PC POS receipt.

It is possible to enter a message that appears on a PC POS receipt.

Accounts where the balance exceeds the limit will automatically be deactivated on the cash register after an end of day extraction.

The GP% report was calculated as a markup rather than a true GP. This has been rectified

The GRV and Ordering modules have been extended to allow for decimal quantities

If a PLU is linked to a stock item where the Stock Type = 1, then the weight sold for that item will appear on the PLU report instead of the quantity.

31 January 2003

Mscomm32.ocx

1.00

Software version 2.08 and later require an updated communication driver. This driver must be copied into the Windows\System directory.

12 March 2003

ECR12Mar03.zip

2.10

Transfer ratio has been included in the Transfer module

A Stock Take Scanner may be used to create an Order

The SFS multiplexor links to all Towa cash registers

A Claims module has been included

A Production module has been included

A specialised Stock GP report has been included for butcheries

An error occurred with Master Stock and Stock Purchases reports because the monthly file was not created during sales extraction. This has been fixed